config root man

Current Path : /compat/linux/proc/68247/cwd/usr/src/contrib/ofed/management/infiniband-diags/man/

FreeBSD hs32.drive.ne.jp 9.1-RELEASE FreeBSD 9.1-RELEASE #1: Wed Jan 14 12:18:08 JST 2015 root@hs32.drive.ne.jp:/sys/amd64/compile/hs32 amd64
Upload File :
Current File : //compat/linux/proc/68247/cwd/usr/src/contrib/ofed/management/infiniband-diags/man/smpdump.8

.TH SMPDUMP 8 "July 25, 2006" "OpenIB" "OpenIB Diagnostics"

.SH NAME
smpdump \- dump InfiniBand subnet management attributes

.SH SYNOPSIS
.B smpdump
[\-s(ring)] [\-D(irect)] [\-C ca_name] [\-P ca_port] [\-t(imeout) timeout_ms] [\-V(ersion)] [\-h(elp)] <dlid|dr_path> <attr> [mod]

.SH DESCRIPTION
.PP
smpdump is a general purpose SMP utility which gets SM attributes from a
specified SMA. The result is dumped in hex by default.

.SH OPTIONS

.TP
attr
IBA attribute ID for SM attribute
.TP
mod
IBA modifier for SM attribute

.SH COMMON OPTIONS

Most OpenIB diagnostics take the following common flags. The exact list of
supported flags per utility can be found in the usage message and can be shown
using the util_name -h syntax.

# Debugging flags
.PP
\-d      raise the IB debugging level.
        May be used several times (-ddd or -d -d -d).
.PP
\-e      show send and receive errors (timeouts and others)
.PP
\-h      show the usage message
.PP
\-v      increase the application verbosity level.
        May be used several times (-vv or -v -v -v)
.PP
\-V      show the version info.

# Addressing flags
.PP
\-D      use directed path address arguments. The path
        is a comma separated list of out ports.
        Examples:
        "0"             # self port
        "0,1,2,1,4"     # out via port 1, then 2, ...
.PP
\-G      use GUID address argument. In most cases, it is the Port GUID.
        Example:
        "0x08f1040023"
.PP
\-s <smlid>      use 'smlid' as the target lid for SM/SA queries.

# Other common flags:
.PP
\-C <ca_name>    use the specified ca_name.
.PP
\-P <ca_port>    use the specified ca_port.
.PP
\-t <timeout_ms> override the default timeout for the solicited mads.

Multiple CA/Multiple Port Support

When no IB device or port is specified, the port to use is selected
by the following criteria:
.PP
1. the first port that is ACTIVE.
.PP
2. if not found, the first port that is UP (physical link up).

If a port and/or CA name is specified, the user request is
attempted to be fulfilled, and will fail if it is not possible.

.SH EXAMPLES

Direct Routed Examples
.PP
smpdump -D 0,1,2,3,5 16 # NODE DESC
.PP
smpdump -D 0,1,2 0x15 2 # PORT INFO, port 2

LID Routed Examples
.PP
smpdump 3 0x15 2        # PORT INFO, lid 3 port 2
.PP
smpdump 0xa0 0x11       # NODE INFO, lid 0xa0

.SH SEE ALSO
.BR smpquery (8)

.SH AUTHOR
.TP
Hal Rosenstock
.RI < halr@voltaire.com >

Man Man