Current Path : /home/usr.opt/mysql57/mysql-test/suite/rpl/t/ |
FreeBSD hs32.drive.ne.jp 9.1-RELEASE FreeBSD 9.1-RELEASE #1: Wed Jan 14 12:18:08 JST 2015 root@hs32.drive.ne.jp:/sys/amd64/compile/hs32 amd64 |
Current File : //home/usr.opt/mysql57/mysql-test/suite/rpl/t/rpl_user_variables.test |
################################### # # Test of replicating user variables # ################################### -- source include/not_group_replication_plugin.inc -- source include/master-slave.inc disable_query_log; call mtr.add_suppression("Unsafe statement written to the binary log using statement format since BINLOG_FORMAT = STATEMENT"); enable_query_log; # Disable PS as the log positions differs --disable_ps_protocol # Clean up old slave's binlogs. # The slave is started with --log-slave-updates # and this test does SHOW BINLOG EVENTS on the slave's # binlog. But previous tests can influence the current test's # binlog (e.g. a temporary table in the previous test has not # been explicitly deleted, or it has but the slave hasn't had # enough time to catch it before STOP SLAVE, # and at the beginning of the current # test the slave immediately writes DROP TEMPORARY TABLE this_old_table). # We wait for the slave to have written all he wants to the binlog # (otherwise RESET MASTER may come too early). --source include/sync_slave_sql_with_master.inc # Save slave's GTID_EXECUTED before issuing a reset master on it. --let $old_gtid_executed= `SELECT @@GLOBAL.GTID_EXECUTED` reset master; connection slave; --source include/stop_slave.inc RESET MASTER; # As the master have a GTID for the suppression added in the beginning of the # test case, we have to make this GTID as purged on slave because we are not # issuing a RESET SLAVE, and the IO thread will not ask for this first # transaction again. Without doing this, the test will fail because the # master's GTID_EXECUTED will differ from slave's the end of the test. --disable_query_log if ( `SELECT @@GLOBAL.GTID_MODE = "ON"` ) { --eval SET @@GLOBAL.GTID_PURGED='$old_gtid_executed' } --enable_query_log --source include/start_slave.inc connection master; create table t1(n char(30)); set @i1:=12345678901234, @i2:=-12345678901234, @i3:=0, @i4:=-1; set @s1:='This is a test', @r1:=12.5, @r2:=-12.5; set @n1:=null; set @s2:='', @s3:='abc\'def', @s4:= 'abc\\def', @s5:= 'abc''def'; insert into t1 values (@i1), (@i2), (@i3), (@i4); insert into t1 values (@r1), (@r2); insert into t1 values (@s1), (@s2), (@s3), (@s4), (@s5); insert into t1 values (@n1); insert into t1 values (@n2); # not explicitely set before insert into t1 values (@a:=0), (@a:=@a+1), (@a:=@a+1); insert into t1 values (@a+(@b:=@a+1)); set @q:='abc'; insert t1 values (@q), (@q:=concat(@q, 'n1')), (@q:=concat(@q, 'n2')); set @a:=5; insert into t1 values (@a),(@a); # To flush the pending event, we add the following statement. RBR can # concatenate the result of several statements, which SBR cannot. select * from t1 where n = '<nonexistant>'; connection master1; # see if variable is reset in binlog when thread changes insert into t1 values (@a),(@a),(@a*5); SELECT * FROM t1 ORDER BY n; --source include/sync_slave_sql_with_master.inc SELECT * FROM t1 ORDER BY n; connection master; insert into t1 select * FROM (select @var1 union select @var2) AS t2; drop table t1; --echo End of 4.1 tests. # BUG#20141 # The following tests ensure that if user-defined variables are used in SF/Triggers # that they are replicated correctly. These tests should be run in both SBR and RBR # modes. # This test uses a procedure that inserts data values based on the value of a # user-defined variable. It also has a trigger that inserts data based on the # same variable. Successful test runs show that the @var is replicated # properly and that the procedure and trigger insert the correct data on the # slave. # # The test of stored procedure was included for completeness. Replication of stored # procedures was not directly affected by BUG#20141. # # This test was constructed for BUG#20141 --disable_warnings DROP TABLE IF EXISTS t20; DROP TABLE IF EXISTS t21; DROP PROCEDURE IF EXISTS test.insert; --enable_warnings CREATE TABLE t20 (a VARCHAR(20)); CREATE TABLE t21 (a VARCHAR(20)); DELIMITER |; # Create a procedure that uses the @var for flow control CREATE PROCEDURE test.insert() BEGIN IF (@VAR) THEN INSERT INTO test.t20 VALUES ('SP_TRUE'); ELSE INSERT INTO test.t20 VALUES ('SP_FALSE'); END IF; END| # Create a trigger that uses the @var for flow control CREATE TRIGGER test.insert_bi BEFORE INSERT ON test.t20 FOR EACH ROW BEGIN IF (@VAR) THEN INSERT INTO test.t21 VALUES ('TRIG_TRUE'); ELSE INSERT INTO test.t21 VALUES ('TRIG_FALSE'); END IF; END| DELIMITER ;| --source include/sync_slave_sql_with_master.inc connection master; # Set @var and call the procedure, repeat with different values SET @VAR=0; CALL test.insert(); SET @VAR=1; CALL test.insert(); --echo On master: Check the tables for correct data SELECT * FROM t20; SELECT * FROM t21; --source include/sync_slave_sql_with_master.inc --echo On slave: Check the tables for correct data and it matches master SELECT * FROM t20; SELECT * FROM t21; connection master; # Cleanup DROP TABLE t20; DROP TABLE t21; DROP PROCEDURE test.insert; # This test uses a stored function that uses user-defined variables to return data # This test was constructed for BUG#20141 --disable_warnings DROP TABLE IF EXISTS t1; DROP FUNCTION IF EXISTS test.square; --enable_warnings CREATE TABLE t1 (i INT); # Create function that returns a value from @var. In this case, the square function CREATE FUNCTION test.square() RETURNS INTEGER DETERMINISTIC RETURN (@var * @var); # Set the @var to different values and insert them into a table SET @var = 1; INSERT INTO t1 VALUES (square()); SET @var = 2; INSERT INTO t1 VALUES (square()); SET @var = 3; INSERT INTO t1 VALUES (square()); SET @var = 4; INSERT INTO t1 VALUES (square()); SET @var = 5; INSERT INTO t1 VALUES (square()); --echo On master: Retrieve the values from the table SELECT * FROM t1; --source include/sync_slave_sql_with_master.inc --echo On slave: Retrieve the values from the table and verify they are the same as on master SELECT * FROM t1; connection master; # Cleanup DROP TABLE t1; DROP FUNCTION test.square; # This test uses stored functions that uses user-defined variables to return data # based on the use of @vars inside a function body. # This test was constructed for BUG#14914 --disable_warnings DROP TABLE IF EXISTS t1; DROP FUNCTION IF EXISTS f1; DROP FUNCTION IF EXISTS f2; --enable_warnings CREATE TABLE t1(a int); DELIMITER |; # Create a function that simply returns the value of an @var. # Create a function that uses an @var for flow control, creates and uses another # @var and sets its value to a value based on another @var. CREATE FUNCTION f1() returns int deterministic BEGIN return @a; END | CREATE FUNCTION f2() returns int deterministic BEGIN IF (@b > 0) then SET @c = (@a + @b); else SET @c = (@a - 1); END if; return @c; END | DELIMITER ;| --source include/sync_slave_sql_with_master.inc connection master; # Set an @var to a value and insert data into a table using the first function. # Set two more @vars to some values and insert data into a table using the second function. SET @a=500; INSERT INTO t1 values(f1()); SET @b = 125; SET @c = 1; INSERT INTO t1 values(f2()); --echo On master: Retrieve the values from the table --source include/sync_slave_sql_with_master.inc connection master; SELECT * from t1; connection slave; --echo On slave: Check the tables for correct data and it matches master SELECT * from t1; connection master; # Cleanup DROP TABLE t1; DROP FUNCTION f1; DROP FUNCTION f2; # This test uses a function that changes a user-defined variable in its body. This test # will ensure the @vars are replicated when needed and not interrupt the normal execution # of the function on the slave. This also applies to procedures and triggers. # This test was constructed for BUG#25167 --disable_warnings DROP TABLE IF EXISTS t1; DROP TABLE IF EXISTS t2; --enable_warnings CREATE TABLE t1 (i int); CREATE TABLE t2 (k int); DELIMITER |; # Create a trigger that inserts data into another table, changes the @var then inserts # another row with the modified value. CREATE trigger t1_bi before INSERT on t1 for each row BEGIN INSERT INTO t2 values (@a); SET @a:=42; INSERT INTO t2 values (@a); END | DELIMITER ;| --source include/sync_slave_sql_with_master.inc connection master; # Set the @var to a value then insert data into first table. SET @a:=100; INSERT INTO t1 values (5); --echo On master: Check to see that data was inserted correctly in both tables SELECT * from t1; SELECT * from t2; --source include/sync_slave_sql_with_master.inc --echo On slave: Check the tables for correct data and it matches master SELECT * from t1; SELECT * from t2; connection master; drop table t1, t2; # # Bug #12826: Possible to get inconsistent slave using SQL syntax Prepared Statements # connection master; create table t1(a int, b int); prepare s1 from 'insert into t1 values (@x:=@x+1, ?)'; set @x=1; execute s1 using @x; select * from t1; --source include/sync_slave_sql_with_master.inc connection slave; select * from t1; connection master; drop table t1; # # Bug#33851: Passing UNSIGNED param to EXECUTE returns ERROR 1210 # connection master; create table t1(a int); insert into t1 values (1),(2); prepare s1 from 'insert into t1 select a from t1 limit ?'; set @x='1.1'; --disable_warnings execute s1 using @x; --enable_warnings select * from t1; --source include/sync_slave_sql_with_master.inc connection slave; select * from t1; connection master; drop table t1; --echo End of 5.0 tests. # This test uses a stored function that uses user-defined variables to return data # The test ensures the value of the user-defined variable is replicated correctly # and in the correct order of assignment. # This test was constructed for BUG#20141 --disable_warnings DROP FUNCTION IF EXISTS f1; DROP FUNCTION IF EXISTS f2; --enable_warnings CREATE TABLE t1 (i INT); # Create two functions. One simply returns the user-defined variable. The other # returns a value based on the user-defined variable. CREATE FUNCTION f1() RETURNS INT RETURN @a; DELIMITER |; CREATE FUNCTION f2() RETURNS INT BEGIN INSERT INTO t1 VALUES (10 + @a); RETURN 0; END| DELIMITER ;| --source include/sync_slave_sql_with_master.inc connection master; # Set the variable and execute the functions. SET @a:=123; SELECT f1(), f2(); --echo On master: Check to see that data was inserted correctly INSERT INTO t1 VALUES(f1()); SELECT * FROM t1; --source include/sync_slave_sql_with_master.inc --echo On slave: Check the table for correct data and it matches master SELECT * FROM t1; connection master; # Cleanup DROP FUNCTION f1; DROP FUNCTION f2; DROP TABLE t1; --source include/sync_slave_sql_with_master.inc --source include/rpl_end.inc