config root man

Current Path : /usr/opt/mysql57/mysql-test/suite/binlog/t/

FreeBSD hs32.drive.ne.jp 9.1-RELEASE FreeBSD 9.1-RELEASE #1: Wed Jan 14 12:18:08 JST 2015 root@hs32.drive.ne.jp:/sys/amd64/compile/hs32 amd64
Upload File :
Current File : //usr/opt/mysql57/mysql-test/suite/binlog/t/binlog_unsafe_stmt_capable_engine.test

# ==== Background ====
#
# Some statements may execute differently on master and slave when
# logged in statement format.  Such statements are called unsafe.
# Unsafe statements include:
#
#  - statements using @@variables (with a small number of exceptions;
#    see below);
#  - statements using certain functions, e.g., UUID();
#  - statements using LIMIT;
#  - insert into two autoinc columns;
#  - statements using UDF's.
#  - statements reading from log tables in the mysql database.
#  - INSERT ... SELECT ... ON DUPLICATE KEY UPDATE
#  - REPLACE ... SELECT
#  - CREATE TABLE [IGNORE/REPLACE] SELECT
#  - INSERT IGNORE...SELECT
#  - UPDATE IGNORE
#  - INSERT... ON DUPLICATE KEY UPDATE on a table with two UNIQUE KEYS
#
# Note that statements that use stored functions, stored procedures,
# triggers, views, or prepared statements that invoke unsafe
# statements shall also be unsafe.
#
# Unsafeness of a statement shall have the following consequences:
#
# 1. If the binlogging is on, for any unsafe statement,
#    - If binlog_format=STATEMENT, the statement shall give a warning.
#    - If binlog_format=MIXED or binlog_format=ROW, the statement shall
#      be logged in row format if the engine is capable of logging in row format.
#
# 2. If the binlogging is on, for any unsafe statement,
#    - If binlog_format=STATEMENT, the statement shall give a warning.
#    - If binlog_format=MIXED or binlog_format=ROW, the statement shall
#      error out if the engine is only statement capable.
#
# 3. If binlogging is off or the statement is not logged (e.g. SELECT
#    UUID()), no warning shall be issued and the statement shall not
#    be logged.
#
# Moreover, when a sub-statement of a recursive construct (i.e.,
# stored function, stored procedure, trigger, view, or prepared
# statement) is unsafe and binlog_format=STATEMENT, then a warning
# shall be issued for every recursive construct.  In effect, this
# creates a stack trace from the top-level statement to the unsafe
# statement.
#
# ==== Purpose ====
#
# Most of this test is copied from the test binlog_unsafe,
# but here we test the logging of unsafe statements when
# storage engine is only capable of logging in statement format.
#
# This test verifies that warning/error is generated when it should,
# according to the above rules when storage engine is only statement capable.
#
# All @@variables should be unsafe, with some exceptions.  Therefore,
# this test also verifies that the exceptions do *not* generate a
# warning.
#
# ==== Method ====
#
# 1. Each type of statements listed above is executed.
#
# 2. Each unsafe statement is wrapped in each type of recursive
#    construct (stored function, stored procedure, trigger, view, or
#    prepared statement).
#
# 3. Each unsafe statement is wrapped in two levels of recursive
#    constructs (function invoking trigger invoking UUID(), etc).
#
# We try to insert the variables that should not be unsafe into a
# table, and verify that *no* warning is issued.
#
# Execute a unsafe statement calling a trigger or stored function
# or neither when SQL_LOG_BIN is turned ON, a warning/error should be issued
# Execute a unsafe statement calling a trigger or stored function
# or neither when @@SQL_LOG_BIN is turned OFF,
# no warning/error is issued
#
# ==== References ====
#
# https://dev.mysql.com/doc/refman/5.6/en/binary-log-mixed.html
#
# ==== Related bugs ====
#
# Bug#28429993: IF THE STORAGE ENGINE SUPPORTS RBR, UNSAFE SQL STATEMENTES END UP IN BINLOG

--source include/have_udf.inc
--source include/have_debug.inc
--source include/have_log_bin.inc
--source include/have_binlog_format_statement.inc
--source include/not_gtid_enabled.inc

--disable_query_log
call mtr.add_suppression("Unsafe statement written to the binary log using statement format since BINLOG_FORMAT = STATEMENT");
--enable_query_log

--echo #### Setup tables ####

CREATE TABLE t0 (a CHAR(100));
CREATE TABLE t1 (a CHAR(100));
CREATE TABLE t2 (a CHAR(100));
CREATE TABLE ta0 (a CHAR(100));
CREATE TABLE ta1 (a CHAR(100));
CREATE TABLE ta2 (a CHAR(100));
CREATE TABLE autoinc_table (a INT PRIMARY KEY AUTO_INCREMENT);
CREATE TABLE data_table (a CHAR(100));
INSERT INTO data_table VALUES ('foo');
CREATE TABLE trigger_table_1 (a INT);
CREATE TABLE trigger_table_2 (a INT);
CREATE TABLE trigger_table_3 (a INT);
CREATE TABLE double_autoinc_table (a INT PRIMARY KEY AUTO_INCREMENT);

# Make the storage engine log only in statement format.
SET @old_debug= @@global.debug;
SET GLOBAL debug='+d,make_stmt_only_engines';

--DELIMITER |
CREATE TRIGGER double_autoinc_trig
BEFORE INSERT ON double_autoinc_table FOR EACH ROW
BEGIN
  INSERT INTO autoinc_table VALUES (NULL);
END|

CREATE FUNCTION multi_unsafe_func() RETURNS INT
BEGIN
  INSERT INTO t0 VALUES(CONCAT(@@hostname, @@hostname));
  INSERT INTO t0 VALUES(0);
  INSERT INTO t0 VALUES(CONCAT(UUID(), @@hostname));
  RETURN 1;
END|
--DELIMITER ;

--replace_result $UDF_EXAMPLE_LIB UDF_EXAMPLE_LIB
--eval CREATE FUNCTION myfunc_int RETURNS INTEGER SONAME "$UDF_EXAMPLE_LIB"

# In each iteration of this loop, we select one method to make the
# statement unsafe.
--let $unsafe_type= 0
while ($unsafe_type < 7) {

  --echo

  if ($unsafe_type == 0) {
    --echo ==== Testing UUID() unsafeness ====
    --let $desc_0= unsafe UUID() function
    --let $stmt_sidef_0= INSERT INTO t0 VALUES (UUID())
    --let $value_0= UUID()
    --let $sel_sidef_0=
    --let $sel_retval_0= SELECT UUID()
    --let $CRC_ARG_expected_number_of_warnings= 1
    --let $CRC_ARG_expected_number_of_deprecation_warnings= 0
  }

  if ($unsafe_type == 1) {
    --echo ==== Testing @@hostname unsafeness ====
    --let $desc_0= unsafe @@hostname variable
    --let $stmt_sidef_0= INSERT INTO t0 VALUES (@@hostname)
    --let $value_0= @@hostname
    --let $sel_sidef_0=
    # $sel_retval is going to be used in views.  Views cannot execute
    # statements that refer to @@variables.  Hence, we set $set_retval
    # to empty instead of SELECT @@hostname.
    --let $sel_retval_0=
    --let $CRC_ARG_expected_number_of_warnings= 1
    --let $CRC_ARG_expected_number_of_deprecation_warnings= 0
  }

  if ($unsafe_type == 2) {
    --echo ==== Testing SELECT...LIMIT unsafeness ====
    --let $desc_0= unsafe SELECT...LIMIT statement
    --let $stmt_sidef_0= INSERT INTO t0 SELECT * FROM data_table LIMIT 1
    --let $value_0=
    --let $sel_sidef_0=
    --let $sel_retval_0= SELECT * FROM data_table LIMIT 1
    --let $CRC_ARG_expected_number_of_warnings= 1
    --let $CRC_ARG_expected_number_of_deprecation_warnings= 0
  }

  if ($unsafe_type == 3) {
    --echo ==== Testing unsafeness of insert of two autoinc values ====
    --let $desc_0= unsafe update of two autoinc columns
    --let $stmt_sidef_0= INSERT INTO double_autoinc_table VALUES (NULL)
    --let $value_0=
    --let $sel_sidef_0=
    --let $sel_retval_0=
    --let $CRC_ARG_expected_number_of_warnings= 1
    --let $CRC_ARG_expected_number_of_deprecation_warnings= 0
  }

  if ($unsafe_type == 4) {
    --echo ==== Testing unsafeness of UDF's ====
    --let $desc_0= unsafe UDF
    --let $stmt_sidef_0= INSERT INTO t0 VALUES (myfunc_int(10))
    --let $value_0= myfunc_int(10)
    --let $sel_sidef_0= SELECT myfunc_int(10)
    --let $sel_retval_0=
    --let $CRC_ARG_expected_number_of_warnings= 1
    --let $CRC_ARG_expected_number_of_deprecation_warnings= 0
  }

  if ($unsafe_type == 5) {
    --echo ==== Testing unsafeness of access to mysql.general_log ====
    --let $desc_0= unsafe use of mysql.general_log
    --let $stmt_sidef_0= INSERT INTO t0 SELECT COUNT(*) FROM mysql.general_log
    --let $value_0=
    --let $sel_sidef_0=
    --let $sel_retval_0= SELECT COUNT(*) FROM mysql.general_log
    --let $CRC_ARG_expected_number_of_warnings= 1
    --let $CRC_ARG_expected_number_of_deprecation_warnings= 0
  }

  if ($unsafe_type == 6) {
    --echo ==== Testing a statement that is unsafe several times ====
    --let $desc_0= statement that is unsafe several times
    --let $stmt_sidef_0= INSERT INTO ta0 VALUES (multi_unsafe_func())
    --let $value_0=
    --let $sel_sidef_0= SELECT multi_unsafe_func()
    --let $sel_retval_0=
    --let $CRC_ARG_expected_number_of_warnings= 2
    --let $CRC_ARG_expected_number_of_deprecation_warnings= 0
  }

  # In each iteration of the following loop, we select one way to
  # enclose the unsafe statement as a sub-statement of a recursive
  # construct (i.e., a function, procedure, trigger, view, or prepared
  # statement).
  #
  # In the last iteration, $call_type_1=7, we don't create a recursive
  # construct. Instead, we just invoke the unsafe statement directly.

  --let $call_type_1= 0
  while ($call_type_1 < 8) {
    #--echo debug: level 1, types $call_type_1 -> $unsafe_type
    --let $CRC_ARG_level= 1
    --let $CRC_ARG_type= $call_type_1
    --let $CRC_ARG_stmt_sidef= $stmt_sidef_0
    --let $CRC_ARG_value= $value_0
    --let $CRC_ARG_sel_sidef= $sel_sidef_0
    --let $CRC_ARG_sel_retval= $sel_retval_0
    --let $CRC_ARG_desc= $desc_0
    --source extra/rpl_tests/create_recursive_construct_stmt_capable_engine.inc
    --let $stmt_sidef_1= $CRC_RET_stmt_sidef
    --let $value_1= $CRC_RET_value
    --let $sel_sidef_1= $CRC_RET_sel_sidef
    --let $sel_retval_1= $CRC_RET_sel_retval
    --let $is_toplevel_1= $CRC_RET_is_toplevel
    --let $drop_1= $CRC_RET_drop
    --let $desc_1= $CRC_RET_desc

    # Some statements must be top-level statements, i.e., cannot be
    # called as a sub-statement of any recursive construct.  (One
    # example is 'EXECUTE prepared_stmt').  When
    # create_recursive_construct_stmt_capable_engine.inc creates a top-level statement, it
    # sets $CRC_RET_is_toplevel=1.

    if (!$is_toplevel_1) {

      # In each iteration of this loop, we select one way to enclose
      # the previous recursive construct in another recursive
      # construct.

      --let $call_type_2= 0
      while ($call_type_2 < 7) {
        #--echo debug: level 2, types $call_type_2 -> $call_type_1 -> $unsafe_type
        --let $CRC_ARG_level= 2
        --let $CRC_ARG_type= $call_type_2
        --let $CRC_ARG_stmt_sidef= $stmt_sidef_1
        --let $CRC_ARG_value= $value_1
        --let $CRC_ARG_sel_sidef= $sel_sidef_1
        --let $CRC_ARG_sel_retval= $sel_retval_1
        --let $CRC_ARG_desc= $desc_1
        --source extra/rpl_tests/create_recursive_construct_stmt_capable_engine.inc
        --let $stmt_sidef_2= $CRC_RET_stmt_sidef
        --let $value_2= $CRC_RET_value
        --let $sel_sidef_2= $CRC_RET_sel_sidef
        --let $sel_retval_2= $CRC_RET_sel_retval
        --let $is_toplevel_2= $CRC_RET_is_toplevel
        --let $drop_2= $CRC_RET_drop
        --let $desc_2= $CRC_RET_desc

        # Drop created object.
        if ($drop_2) {
          --eval $drop_2
        }
        --inc $call_type_2
      } # while (call_type_2)
    } # if (!is_toplevel_1)

    # Drop created object.
    if ($drop_1) {
      --eval $drop_1
    }
    --inc $call_type_1
  } # while (call_type_1)

  --inc $unsafe_type
} # while (unsafe_type)

DROP TRIGGER double_autoinc_trig;
DROP TABLE t0, t1, t2, ta0, ta1, ta2,
  autoinc_table, double_autoinc_table,
  data_table,
  trigger_table_1, trigger_table_2, trigger_table_3;
DROP FUNCTION myfunc_int;
DROP FUNCTION multi_unsafe_func;


--echo ==== Special system variables that should *not* be unsafe ====

CREATE TABLE t1 (a VARCHAR(1000));
CREATE TABLE autoinc_table (a INT PRIMARY KEY AUTO_INCREMENT);

INSERT INTO t1 VALUES (@@session.auto_increment_increment);
INSERT INTO t1 VALUES (@@session.auto_increment_offset);
INSERT INTO t1 VALUES (@@session.character_set_client);
INSERT INTO t1 VALUES (@@session.character_set_connection);
INSERT INTO t1 VALUES (@@session.character_set_database);
INSERT INTO t1 VALUES (@@session.character_set_server);
INSERT INTO t1 VALUES (@@session.collation_connection);
INSERT INTO t1 VALUES (@@session.collation_database);
INSERT INTO t1 VALUES (@@session.collation_server);
INSERT INTO t1 VALUES (@@session.foreign_key_checks);
INSERT INTO t1 VALUES (@@session.identity);
INSERT INTO t1 VALUES (@@session.last_insert_id);
INSERT INTO t1 VALUES (@@session.lc_time_names);
INSERT INTO t1 VALUES (@@session.pseudo_thread_id);
INSERT INTO t1 VALUES (@@session.sql_auto_is_null);
INSERT INTO t1 VALUES (@@session.timestamp);
INSERT INTO t1 VALUES (@@session.time_zone);
INSERT INTO t1 VALUES (@@session.unique_checks);

SET @my_var= 4711;
INSERT INTO t1 VALUES (@my_var);

# using insert_id implicitly should be ok.
SET insert_id= 12;
INSERT INTO autoinc_table VALUES (NULL);

# See set_var.cc for explanation.
--echo The following variables *should* give a warning, despite they are replicated.
INSERT INTO t1 VALUES (@@session.sql_mode);
INSERT INTO t1 VALUES (@@session.insert_id);


DROP TABLE t1, autoinc_table;

# Clean up
SET GLOBAL debug= @old_debug;
--echo "End of tests"

Man Man