Current Path : /usr/share/snmp/mibs/ |
FreeBSD hs32.drive.ne.jp 9.1-RELEASE FreeBSD 9.1-RELEASE #1: Wed Jan 14 12:18:08 JST 2015 root@hs32.drive.ne.jp:/sys/amd64/compile/hs32 amd64 |
Current File : //usr/share/snmp/mibs/BEGEMOT-ATM.txt |
-- -- Copyright (c) 2001-2002 -- Fraunhofer Institute for Open Communication Systems (FhG Fokus). -- All rights reserved. -- Copyright (c) 2004 -- Hartmut Brandt. -- All rights reserved. -- -- Author: Hartmut Brandt <harti@freebsd.org> -- -- Redistribution and use in source and binary forms, with or without -- modification, are permitted provided that the following conditions -- are met: -- 1. Redistributions of source code must retain the above copyright -- notice, this list of conditions and the following disclaimer. -- 2. Redistributions in binary form must reproduce the above copyright -- notice, this list of conditions and the following disclaimer in the -- documentation and/or other materials provided with the distribution. -- -- THIS SOFTWARE IS PROVIDED BY AUTHOR AND CONTRIBUTORS ``AS IS'' AND -- ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE -- IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE -- ARE DISCLAIMED. IN NO EVENT SHALL AUTHOR OR CONTRIBUTORS BE LIABLE -- FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL -- DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS -- OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) -- HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT -- LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY -- OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF -- SUCH DAMAGE. -- -- $Begemot: libunimsg/snmp_atm/BEGEMOT-ATM.txt,v 1.2 2004/08/06 14:50:26 brandt Exp $ -- -- Private Begemot MIB for ATM interfaces. -- BEGEMOT-ATM-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, Unsigned32, TimeTicks FROM SNMPv2-SMI TEXTUAL-CONVENTION, DisplayString FROM SNMPv2-TC ifIndex FROM IF-MIB begemot FROM BEGEMOT-MIB; begemotAtm MODULE-IDENTITY LAST-UPDATED "200407190000Z" ORGANIZATION "German Aerospace Centre" CONTACT-INFO " Hartmut Brandt Postal: German Aerospace Centre (DLR) Institute of Communications and Navigation 82234 Wessling Germany Fax: +49 8153 28 2844 E-mail: harti@freebsd.org" DESCRIPTION "The Begemot MIB for ATM interfaces." ::= { begemot 101 } begemotAtmObjects OBJECT IDENTIFIER ::= { begemotAtm 1 } -- -------------------------------------------------------------------------- AtmESI ::= TEXTUAL-CONVENTION DISPLAY-HINT "1x:" STATUS current DESCRIPTION "An ATM End System Identifier. This is basically the same as an Ethernet Address and is assigned using the same rules." SYNTAX OCTET STRING (SIZE(6)) -- -------------------------------------------------------------------------- -- -- Interfaces table -- begemotAtmIfTable OBJECT-TYPE SYNTAX SEQUENCE OF BegemotAtmIfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains an entry for each hardware ATM interface. The table is indexed by the interface index." ::= { begemotAtmObjects 1 } begemotAtmIfEntry OBJECT-TYPE SYNTAX BegemotAtmIfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is a table entry describing one ATM hardware interface." INDEX { ifIndex } ::= { begemotAtmIfTable 1 } BegemotAtmIfEntry ::= SEQUENCE { begemotAtmIfName DisplayString, begemotAtmIfPcr Unsigned32, begemotAtmIfMedia INTEGER, begemotAtmIfVpiBits Unsigned32, begemotAtmIfVciBits Unsigned32, begemotAtmIfMaxVpcs Unsigned32, begemotAtmIfMaxVccs Unsigned32, begemotAtmIfEsi AtmESI, begemotAtmIfCarrierStatus INTEGER, begemotAtmIfMode INTEGER } begemotAtmIfName OBJECT-TYPE SYNTAX DisplayString (SIZE(1..15)) MAX-ACCESS read-only STATUS current DESCRIPTION "Name of the ATM interface." ::= { begemotAtmIfEntry 1 } begemotAtmIfPcr OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The line cell rate of the interface." ::= { begemotAtmIfEntry 2 } begemotAtmIfMedia OBJECT-TYPE SYNTAX INTEGER { other(1), unknown(3), utp25(4), taxi100(5), taxi140(6), mm155(7), sm155(8), utp155(9), mm622(10), sm622(11), virtual(12) } MAX-ACCESS read-only STATUS current DESCRIPTION "The physical medium." ::= { begemotAtmIfEntry 3 } begemotAtmIfVpiBits OBJECT-TYPE SYNTAX Unsigned32 (0..12) MAX-ACCESS read-only STATUS current DESCRIPTION "Number of VPI bits that are used by the device." ::= { begemotAtmIfEntry 4 } begemotAtmIfVciBits OBJECT-TYPE SYNTAX Unsigned32 (0..16) MAX-ACCESS read-only STATUS current DESCRIPTION "Number of VCI bits that are used by the device." ::= { begemotAtmIfEntry 5 } begemotAtmIfMaxVpcs OBJECT-TYPE SYNTAX Unsigned32 (0..256) MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum number of VPC supported on this device. This may not be larger than 2^begemotAtmIfVpiBits." ::= { begemotAtmIfEntry 6 } begemotAtmIfMaxVccs OBJECT-TYPE SYNTAX Unsigned32 (0..16777216) MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum number of VCC supported on this device. This may not be larger than 2^(begemotAtmIfVpiBits + begemotAtmVciBits)." ::= { begemotAtmIfEntry 7 } begemotAtmIfEsi OBJECT-TYPE SYNTAX AtmESI MAX-ACCESS read-only STATUS current DESCRIPTION "The default End System Identifier as reported by the hardware. If the hardware has no ESI all six bytes are reported as 0." ::= { begemotAtmIfEntry 8 } begemotAtmIfCarrierStatus OBJECT-TYPE SYNTAX INTEGER { carrierOn(1), carrierOff(2), unknown(3), none(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "The state of the carrier. For interfaces which don't have the notion of a carriere none is reported." ::= { begemotAtmIfEntry 9 } begemotAtmIfMode OBJECT-TYPE SYNTAX INTEGER { sonet(1), sdh(2), unknown(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The mode of the SUNI interface. For interfaces without SUNI unknown is reported in which case the variable is read-only. Some types of interfaces may not be able to change this value." ::= { begemotAtmIfEntry 10 } begemotAtmIfTableLastChange OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "The value of sysUpTime the last time that an entry in begemotIfTable was created or destroyed. If the table is unchanged since the last coldStart this value is zero." ::= { begemotAtmObjects 2 } -- -- Interface hardware table -- begemotAtmHWTable OBJECT-TYPE SYNTAX SEQUENCE OF BegemotAtmHWEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table augments the begemotAtmIfTable and contains an entry for each hardware ATM interface. The entries describe the ATM hardware interface." ::= { begemotAtmObjects 3 } begemotAtmHWEntry OBJECT-TYPE SYNTAX BegemotAtmHWEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is a table entry describing one ATM hardware interface." AUGMENTS { begemotAtmIfEntry } ::= { begemotAtmHWTable 1 } BegemotAtmHWEntry ::= SEQUENCE { begemotAtmHWVendor DisplayString, begemotAtmHWDevice DisplayString, begemotAtmHWSerial Unsigned32, begemotAtmHWVersion Unsigned32, begemotAtmHWSoftVersion Unsigned32 } begemotAtmHWVendor OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "A short string naming the vendor of the interface card." ::= { begemotAtmHWEntry 1 } begemotAtmHWDevice OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "A short string naming the brand of the interface card." ::= { begemotAtmHWEntry 2 } begemotAtmHWSerial OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The serial number of the interface card or 0 if it doesn't report a serial number." ::= { begemotAtmHWEntry 3 } begemotAtmHWVersion OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The hardware version of the interface card or 0 if it doesn't report a hardware version number." ::= { begemotAtmHWEntry 4 } begemotAtmHWSoftVersion OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The firmware version of the interface card or 0 if it doesn't report a firmware version number." ::= { begemotAtmHWEntry 5 } -- -------------------------------------------------------------------- -- System specific parts begemotAtmSysGroup OBJECT IDENTIFIER ::= { begemotAtmObjects 4 } END