config root man

Current Path : /usr/src/usr.sbin/bsnmpd/modules/snmp_bridge/

FreeBSD hs32.drive.ne.jp 9.1-RELEASE FreeBSD 9.1-RELEASE #1: Wed Jan 14 12:18:08 JST 2015 root@hs32.drive.ne.jp:/sys/amd64/compile/hs32 amd64
Upload File :
Current File : //usr/src/usr.sbin/bsnmpd/modules/snmp_bridge/RSTP-MIB.txt

--
-- Copyright (C) The Internet Society (2005).
--
-- This document is subject to the rights, licenses and restrictions
-- contained in BCP 78, and except as set forth therein, the authors
-- retain all their rights.
--
-- This document and the information contained herein are provided on an
-- "AS IS" basis and THE CONTRIBUTOR, THE ORGANIZATION HE/SHE REPRESENTS
-- OR IS SPONSORED BY (IF ANY), THE INTERNET SOCIETY AND THE INTERNET
-- ENGINEERING TASK FORCE DISCLAIM ALL WARRANTIES, EXPRESS OR IMPLIED,
-- INCLUDING BUT NOT LIMITED TO ANY WARRANTY THAT THE USE OF THE
-- INFORMATION HEREIN WILL NOT INFRINGE ANY RIGHTS OR ANY IMPLIED
-- WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
--
-- $FreeBSD: release/9.1.0/usr.sbin/bsnmpd/modules/snmp_bridge/RSTP-MIB.txt 164997 2006-12-07 22:36:17Z syrinx $
--

RSTP-MIB DEFINITIONS ::= BEGIN

-- -------------------------------------------------------------
-- MIB for IEEE 802.1w Rapid Spanning Tree Protocol
-- -------------------------------------------------------------

IMPORTS
    MODULE-IDENTITY, OBJECT-TYPE, Integer32, mib-2
        FROM SNMPv2-SMI
    TruthValue
        FROM SNMPv2-TC
    MODULE-COMPLIANCE, OBJECT-GROUP
        FROM SNMPv2-CONF
    dot1dStp, dot1dStpPortEntry
        FROM BRIDGE-MIB;

rstpMIB MODULE-IDENTITY
    LAST-UPDATED "200512070000Z"
    ORGANIZATION "IETF Bridge MIB Working Group"
    CONTACT-INFO
        "Email: Bridge-mib@ietf.org"
    DESCRIPTION
        "The Bridge MIB Extension module for managing devices
         that support the Rapid Spanning Tree Protocol defined
         by IEEE 802.1w.

         Copyright (C) The Internet Society (2005).  This version of
         this MIB module is part of RFC 4318; See the RFC itself for
         full legal notices."

    REVISION     "200512070000Z"
    DESCRIPTION
         "The initial version of this MIB module as published in
          RFC 4318."
    ::= { mib-2 134 }

-- ---------------------------------------------------------- --
-- subtrees in the RSTP-MIB
-- ---------------------------------------------------------- --

rstpNotifications OBJECT IDENTIFIER ::= { rstpMIB 0 }
rstpObjects       OBJECT IDENTIFIER ::= { rstpMIB 1 }
rstpConformance   OBJECT IDENTIFIER ::= { rstpMIB 2 }

-- -------------------------------------------------------------
-- Addition to the dot1dStp group
-- -------------------------------------------------------------

dot1dStpVersion OBJECT-TYPE
    SYNTAX      INTEGER {
                    stpCompatible(0),
                    rstp(2)
                }
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The version of Spanning Tree Protocol the bridge is
         currently running.  The value 'stpCompatible(0)'
         indicates the Spanning Tree Protocol specified in
         IEEE 802.1D-1998 and 'rstp(2)' indicates the Rapid
         Spanning Tree Protocol specified in IEEE 802.1w and
         clause 17 of 802.1D-2004.  The values are directly from
         the IEEE standard.  New values may be defined as future
         versions of the protocol become available.

         The value of this object MUST be retained across
         reinitializations of the management system."
    REFERENCE
        "IEEE 802.1w clause 14.8.1, 17.12, 17.16.1"
    DEFVAL      { rstp }
    ::= { dot1dStp 16 }

dot1dStpTxHoldCount OBJECT-TYPE
    SYNTAX      Integer32 (1..10)
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The value used by the Port Transmit state machine to limit
         the maximum transmission rate.

         The value of this object MUST be retained across
         reinitializations of the management system."

    REFERENCE
        "IEEE 802.1w clause 17.16.6"
    DEFVAL      { 3 }
    ::= { dot1dStp 17 }

--
-- { dot1dStp 18 } was used to represent dot1dStpPathCostDefault
-- in an earlier version of this MIB.  It has since been
-- obsoleted, and should not be used.
--

dot1dStpExtPortTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF Dot1dStpExtPortEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "A table that contains port-specific Rapid Spanning Tree
         information."
    ::= { dot1dStp 19 }

dot1dStpExtPortEntry OBJECT-TYPE
    SYNTAX      Dot1dStpExtPortEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "A list of Rapid Spanning Tree information maintained by
         each port."
    AUGMENTS    { dot1dStpPortEntry }
    ::= { dot1dStpExtPortTable 1 }

Dot1dStpExtPortEntry ::=
    SEQUENCE {
        dot1dStpPortProtocolMigration
            TruthValue,
        dot1dStpPortAdminEdgePort
            TruthValue,
        dot1dStpPortOperEdgePort
            TruthValue,
        dot1dStpPortAdminPointToPoint
            INTEGER,
        dot1dStpPortOperPointToPoint
            TruthValue,
        dot1dStpPortAdminPathCost
            Integer32
    }

dot1dStpPortProtocolMigration OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "When operating in RSTP (version 2) mode, writing true(1)
         to this object forces this port to transmit RSTP BPDUs.
         Any other operation on this object has no effect and
         it always returns false(2) when read."
    REFERENCE
        "IEEE 802.1w clause 14.8.2.4, 17.18.10, 17.26"
    ::= { dot1dStpExtPortEntry 1 }

dot1dStpPortAdminEdgePort OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The administrative value of the Edge Port parameter.  A
         value of true(1) indicates that this port should be
         assumed as an edge-port, and a value of false(2) indicates
         that this port should be assumed as a non-edge-port.
         Setting this object will also cause the corresponding
         instance of dot1dStpPortOperEdgePort to change to the
         same value.  Note that even when this object's value
         is true, the value of the corresponding instance of
         dot1dStpPortOperEdgePort can be false if a BPDU has
         been received.

         The value of this object MUST be retained across
         reinitializations of the management system."

    REFERENCE
        "IEEE 802.1t clause 14.8.2, 18.3.3"
    ::= { dot1dStpExtPortEntry 2 }

dot1dStpPortOperEdgePort OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The operational value of the Edge Port parameter.  The
         object is initialized to the value of the corresponding
         instance of dot1dStpPortAdminEdgePort.  When the
         corresponding instance of dot1dStpPortAdminEdgePort is
         set, this object will be changed as well.  This object
         will also be changed to false on reception of a BPDU."

    REFERENCE
        "IEEE 802.1t clause 14.8.2, 18.3.4"
    ::= { dot1dStpExtPortEntry 3 }

dot1dStpPortAdminPointToPoint OBJECT-TYPE
    SYNTAX      INTEGER {
                    forceTrue(0),
                    forceFalse(1),
                    auto(2)
                }
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The administrative point-to-point status of the LAN segment
         attached to this port, using the enumeration values of the
         IEEE 802.1w clause.  A value of forceTrue(0) indicates
         that this port should always be treated as if it is
         connected to a point-to-point link.  A value of
         forceFalse(1) indicates that this port should be treated as
         having a shared media connection.  A value of auto(2)
         indicates that this port is considered to have a
         point-to-point link if it is an Aggregator and all of its
         members are aggregatable, or if the MAC entity
         is configured for full duplex operation, either through
         auto-negotiation or by management means.  Manipulating this
         object changes the underlying adminPortToPortMAC.

         The value of this object MUST be retained across
         reinitializations of the management system."

   REFERENCE
       "IEEE 802.1w clause 6.4.3, 6.5, 14.8.2"
   ::= { dot1dStpExtPortEntry 4 }

dot1dStpPortOperPointToPoint OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The operational point-to-point status of the LAN segment
         attached to this port.  It indicates whether a port is
         considered to have a point-to-point connection.
         If adminPointToPointMAC is set to auto(2), then the value
         of operPointToPointMAC is determined in accordance with the
         specific procedures defined for the MAC entity concerned,
         as defined in IEEE 802.1w, clause 6.5.  The value is
         determined dynamically; that is, it is re-evaluated whenever
         the value of adminPointToPointMAC changes, and whenever
         the specific procedures defined for the MAC entity evaluate
         a change in its point-to-point status."
    REFERENCE
        "IEEE 802.1w clause 6.4.3, 6.5, 14.8.2"
    ::= { dot1dStpExtPortEntry 5 }

dot1dStpPortAdminPathCost OBJECT-TYPE
    SYNTAX      Integer32 (0..200000000)
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The administratively assigned value for the contribution
         of this port to the path cost of paths toward the spanning
         tree root.

         Writing a value of '0' assigns the automatically calculated
         default Path Cost value to the port.  If the default Path
         Cost is being used, this object returns '0' when read.

         This complements the object dot1dStpPortPathCost or
         dot1dStpPortPathCost32, which returns the operational value
         of the path cost.

         The value of this object MUST be retained across
         reinitializations of the management system."
    REFERENCE
        "IEEE 802.1D-1998: Section 8.5.5.3"
    ::= { dot1dStpExtPortEntry 6 }

-- -------------------------------------------------------------
-- rstpMIB - Conformance Information
-- -------------------------------------------------------------

rstpGroups OBJECT IDENTIFIER ::= { rstpConformance 1 }

rstpCompliances OBJECT IDENTIFIER ::= { rstpConformance 2 }

-- -------------------------------------------------------------
-- Units of conformance
-- -------------------------------------------------------------

rstpBridgeGroup OBJECT-GROUP
    OBJECTS {
        dot1dStpVersion,
        dot1dStpTxHoldCount
    }
    STATUS      current
    DESCRIPTION
        "Rapid Spanning Tree information for the bridge."
    ::= { rstpGroups 1 }

rstpPortGroup OBJECT-GROUP
    OBJECTS {
        dot1dStpPortProtocolMigration,
        dot1dStpPortAdminEdgePort,
        dot1dStpPortOperEdgePort,
        dot1dStpPortAdminPointToPoint,
        dot1dStpPortOperPointToPoint,
        dot1dStpPortAdminPathCost
    }
    STATUS      current
    DESCRIPTION
        "Rapid Spanning Tree information for individual ports."
    ::= { rstpGroups 2 }

-- -------------------------------------------------------------
-- Compliance statements
-- -------------------------------------------------------------

rstpCompliance MODULE-COMPLIANCE
    STATUS      current
    DESCRIPTION
        "The compliance statement for device support of Rapid
         Spanning Tree Protocol (RSTP) bridging services."
    MODULE
        MANDATORY-GROUPS {
            rstpBridgeGroup,
            rstpPortGroup
        }
    ::= { rstpCompliances 1 }

END

Man Man